System Sensor i3 sounder and relay smoke detectors apply the guiding principles of installation ease, intelligence, and instant inspection in a series of specialty conventional devices. Installation ease. Throughout the i3 series, installation is simple with its installer-friendly base and plug-in design. The base accommodates a broad range of back box and direct mounting options and provides ample space for pre-wiring the device. To complete the installation, the i3 detector plugs into its base with a simple Stop-Drop ’N Lock action. Intelligence. To reduce the likelihood of nuisance alarms, all i3 detectors are equipped with both drift compensation and smoothing algorithms. These capabilities minimize both short- and long-term causes of nuisance alarms, such as RF interference and dust accumulation. When connected to the 2W-MOD2 loop test/ maintenance module or an i3 ReadyTM panel, 2-wire i3 detectors can generate a remote maintenance signal when in a maintenance or freeze trouble condition. To measure the sensitivity of any i3 detector, the SENS-RDR displays the reading, in terms of percent-per-foot obscuration, within seconds. Instant inspection. i3 has red and green LEDs to simplify local status indication during power-up, standby, alarm, maintenance, and freeze trouble conditions. When in alarm, i3 sounder models generate an 85 dB temporal tone. If connected to the RRS-MOD reversing relay/synchronization module, all i3 sounders on the loop will activate when one detector is in alarm. The RRS-MOD also synchronizes i3 sounder output to ensure a clear audible signal. Should the application call for differentiating between a local and a general alarm, the i3 line offers an isolated thermal model, which initiates a local alarm when smoke is detected, and a general alarm when the thermal sensor is activated.
Product Specs:
Brand | System Sensor |
MPN | 2WTR-B |
Model | i3 |
Alarm Current | 130mA max, limited by panel |
Auxiliary Contact | Form C |
Auxiliary Contact Ratings | 2A @ 30V AC/DC |
Detection | Photoelectric |
Dimensions | 2″/51mm H x 5.3″/127mm Dia. |
Freeze Trouble | 41F/5C |
Heat Sensor | 135F/57.2C fixed |
Humidity Range | 0-95% RH, noncondensing |
Max Ripple Voltage | 30% of applied voltage (peak to peak) |
Operating Voltage | 12/24V non-polarized nominal, 8.5 min. to 35 max. |
Sensitivity | 2.5%/ft. nominal |
Standby Current | 50A max. avg. 100A peak |
Temperature Range | 32-100F/0-37.8C |
Weight | 7.1 oz/200 g |
Wiring | 2-wire |
Wiring Gauge | 14-22 AWG |