Toll Free: 800-431-2912 (USA ONLY)

My Account   |   Contact Us   |   Careers     

FT3120-E4S40

Please call 845-790-9900 for a quote or send an RFQ through our “Request for Quote” tab.

FT 3120® and FT 3150® Free Topology Smart Transceiver

Categories: ,

Description

Item Description:

The FT3120-E4S40 Smart Transceiver integrates a high-performance Neuron® Core with a free topology twisted-pair transceiver in a 32-SOIC housing. It only requires a transformer like the FT-X1, FT-X2 or FT-X3 .

Product Specs:

Brand Echelon
MPN FT3120-E4S40
Model FT 3120
Data Communications Type Differential Manchester coding
Network Polarity Polarity insensitive
Isolation Between Network and 0-60Hz, 60 seconds 1000Vrms
Isolation Between Network and 0-60Hz, continuous 277Vrms
EMI Designed to comply with FCC Part 15 Level B and EN55022 Level B
ESD Designed to comply with EN 61000-4-2, Level 4
Radiated Electromagnetic Susceptibility Designed to comply with EN 61000-4-3, Level 3
Fast Transient/Burst Immunity Designed to comply with EN 61000-4-4, Level 4
Surge Immunity Designed to comply with EN 61000-4-5, Level 3
Conducted RF Immunity Designed to comply with EN 61000-4-6, Level 3
Safety Approvals (FT-X1/FT-X2 Communication Transformer) Recognized by UL to Standards UL 60950, 2000 and CSA C22.2 No. 60950, 2000; Recognized by TÜV EN 60950
Transmission Speed 78 kilobits per second
Number of Transceivers Per Segment Up to 64
Network Wiring 24 to 16AWG twisted pair
Network Length in Free Topology 1000m (3,280 feet) maximum total wire with one repeater

500m (1,640 feet) maximum total wire with no repeaters

500m (1,640 feet) maximum device-to-device distance

Network Length in Doubly Terminated Bus Topology 5400m (17,710 feet) with one repeater

2700m (8,850 feet) with no repeaters

Maximum Stub Length in Doubly-Terminated Bus Topology 3m (9.8 feet)
Network Termination One terminator in free topology; two terminators in bus topology
Power-down Network Protection High impedance when unpowered
Physical Layer Repeater The FT 3120/FT 3150 Free Topology Smart Transceiver cannot be used to implement a physical layer repeater. In the event that the limits on the number of transceivers or total wire distance are exceeded, FTT-10A transceivers may be used to create physical layer repeaters.
Operating Temperature -40 to 85°C
Operating Humidity 25-90% RH @50°C, non-condensing
Non-operating Humidity 95% RH @ 50°C, non-condensing
Vibration 1.5g peak-to-peak, 8Hz-2kHz
Mechanical Shock 100g (peak)